Adlink HSL-4XMO Manual de usuario Pagina 43

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 116
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 42
Operation Theory 33
Figure 4-2: Single Command Timing
The base scan time table is as follows, N is the range of total IDs.
Half Duplex Full Duplex Maximum Length
3M 118 us x N 60.7 us x N 400 meters
6M 59 us x N 30.4 us x N 200 meters
12M 29.5 us x N 15.2 us x N 100 meters
Table 4-1: Base Scan Times
Vista de pagina 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48 ... 115 116

Comentarios a estos manuales

Sin comentarios