Adlink ACL-8112 Series Manual de usuario Pagina 62

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 92
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 61
54 C Language Library
7.1 _8112_Initial
Description
All ACL-8112 cards are initialized according to its card number and its
corresponding base address. Every ACL-8112 Multi-Function Data
Acquisition Card must be initialized using this function before any other
function calls are permitted.
Syntax
int _8112_Initial(int card_number, int type, int
base_addresss )
int _8112pg_Initial(int card_number, int
base_addresss )
Argument:
card_number:
the card number to be initialized, only
two cards can be initialized, the card
number must be CARD_1 or CARD_2.
Type :
there are 4 different types of ACL-8112
cards, they are:
A8112B_ HG: 8112 High Gain card Ver. B
A8112B_DG: 8112 Low Gain card Ver. B
A8112C_HG: 8112 High Gain card Ver. C
A8112C_DG: 8112 Low Gain card Ver. C
Note: the difference between Ver.B and
Ver.C is the Multi-Scan Register. The
control code for each version is
slight different. For details, please
refer to the hardware manual for the
specific ACL-8112 card.
base_address:
the I/O port base address of the card
is set at 220 Hex default.
Return Code:
ERR_NoError
ERR_InvalidBoardNumber
ERR_BaseAddressError
Vista de pagina 61
1 2 ... 57 58 59 60 61 62 63 64 65 66 67 ... 91 92

Comentarios a estos manuales

Sin comentarios