Adlink ACL-8112 Series Manual de usuario Pagina 35

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 92
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 34
Signal Connections 27
If your signal sources contain both a floating and a local ground, you
should use the differential mode, with the floating signal source connected
as Figure 3.7 .
AIHn
AILn
n = 0, ..., 8
Floatin
Signal
Sourc
To A/D Converter
High
Low
GND
Figure 3.7 Floating source and differential input
Vista de pagina 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 91 92

Comentarios a estos manuales

Sin comentarios