Adlink ACL-8112 Series Manual de usuario Pagina 27

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 92
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 26
Installation 19
2.11 D/A Reference Voltage Setting
The D/A converter's reference voltage source can be internally or externally
generated. The external reference voltage is connected via CN3 pin
31(ExtRef1) and pin 12(ExtRef2), see section 3.1. The D/A reference source
of channel 1 and channel 2 are selected using JP2 for the ACL-8112DG/HG
and JP6 and JP7 for the ACL-8112PG respectively. Possible settings are
shown below:
Figure 2.8 D/A Voltage Setting
D/A CH1 is External
D/A CH2 is External
JP2 or JP7 JP6
INTREF
ExtRef2 ExtRef1
INTREF
D/A CH1 is External
D/A CH2 is Internal
D/A CH1 is Internal
D/A CH2 is External
D/A CH1 is Internal
D/A CH2 is Internal
JP2 or JP7 JP6
INTREF
ExtRef2 ExtRef1
INTREF
JP2 or JP7 JP6
INTREF
ExtRef2
ExtRef1
INTREF
JP2 or JP7 JP6
INTREF
ExtRef2
ExtRef1
INTREF
Vista de pagina 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 91 92

Comentarios a estos manuales

Sin comentarios