10 User's Manual
1.2.15.ElectromagneticImmunity
ElectromagneticImmunitytestsassumetheSSDisproperlyinstalledintherepresentativehostsystem.The
driveoperatesproperlywithouterrorsdegradationinperformancewhensubjectedtoradiofrequency(RF)
environmentsdefinedinthefollowingtable.
Test Description Performancecriteria Referencestandard
Electrostaticdischarge
Contact,HCP,VCP:±8KV
Air:±15KV
B EN61000‐4‐2:95
RadiatedRFimmunity
80~1000MHz,3V/m,
80%AMwith1KHzsine
900MHz,3V/m,50%
pulsemodulationat
200Hz
A
EN61000‐4‐3:96
ENV50204:95
Electricalfasttransient
±1KVonACmains
±0.5KVonexternalI/O
B EN61000‐4‐4:95
Surgeimmunity
±1KVdifferential±2KV
common,ACmains
B EN61000‐4‐5:95
ConductedRFimmunity
150KHz~80MHz,3Vrms,
80%AMwith1KHzsine
A EN61000‐4‐6:97
Voltagedips,interrupts
0%open,5sec
0%short,5sec
40%,0.10sec
70%,0.01sec
C
C
C
B
EN61000‐4‐11:94
Table12:RadioFrequencySpecifications
Notes:
1. PerformancecriterionA=Thedeviceshallcontinuetooperateasintended,i.e.,normal
unitoperationwithnodegradationofperformance.
2. PerformancecriterionB=Thedeviceshallcontinuetooperateasintendedafter
completionoftest,however,duringthetest,somedegradation
ofperformanceisallowed
aslongasthereisnodatalossoperatorinterventiontorestoredevicefunction.
3. PerformancecriterionC=Temporarylossoffunctionisallowed.Operatorinterventionis
acceptabletorestoredevicefunction.
4. Contactelectrostaticdischargeisappliedtodriveenclosure.
1.2.16.Weight:80g
Max(withcase)
1.2.17.Dimension:100.0mmx69.8mmx9.5mm(LxWxH)
1.2.18.PartNumbers:
PartNo. ProductName Temperature
92‐99059‐0210 ASD25‐SLC32G‐ET‐40°C~+85°C
92‐99059‐0010 ASD25‐SLC64G‐ET‐40°C~+85°C
92‐99059‐0110 ASD25‐SLC128G‐ET‐40°C~+85°C
92‐99059‐0310 ASD25‐SLC32G‐CT 0°C~+70°C
92‐99059‐1010 ASD25‐SLC64G‐CT 0°C~+70°C
92‐99059‐2010 ASD25‐SLC128G‐CT 0°C~+70°C
Comentarios a estos manuales