44 Operation Theory
Figure 4-15: Stop Mode II
Stop Mode III
After a mode III stop trigger is asserted, the waveform genera-
tion continues until the iterative number of waveforms specified
in IC_Counter is completed. Figure 4-16 is shown as an exam-
ple. Since IC_Counter is set to three, the total generated wave-
forms must be a multiple of three.
You can check WFG_in_progress (waveform generation in
progress) status by software read-back to confirm the stop of a
waveform generation.