Adlink DAQe-2502 Manual de usuario Pagina 38

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 74
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 37
28 Operation Theory
Post-Trigger or Delay-trigger Acquisition with Retrigger
Use post-trigger or delay-trigger acquisition with retrigger when
you want to perform repeated scans with respect to the
repeated triggers. Figure 4-4 illustrates this mode. Two scans
are performed after the first trigger signal, and then waits for
the next trigger signal. When the trigger signal occurs, it per-
forms two more scans.
When retrigger function is disabled, only one trigger signal is
be accepted after retrigger.
NOTE Retrigger signals asserted during scan process will be ig-
nored.
Figure 4-4: Post Trigger with Retrigger
Vista de pagina 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 73 74

Comentarios a estos manuales

Sin comentarios