Vista de pagina 34
Signal Connections
27
If your signal sources contain both a floating and a local ground, you
should use the differential mode, with the floating signal source connected
as Figure 3.7 .
A
IHn
A
ILn
n = 0, ..., 8
Floatin
Si
g
nal
Sourc
To A/D Converter
High
Low
GND
Figure 3.7 Floating source and differential input