Adlink PCI-8164 Manual de usuario Pagina 170

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 310
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 169
158 Motion Creator
7. Operation Mode: Select operation mode.
Z Absolute Mode: Sets the Position1 and Position2 as
absolution target positions for motion. The related func-
tions are _8164_start_ta_move(),
_8164_start_sa_move().
Z Relative Mode: Uses Distance as relative displacement
for motion. The related function is
_8164_start_tr_move(),
_8164_start_sr_move().
Z Cont. Move: Velocity motion mode. The related function
is _8164_tv_move(), _8164_start_sv_move().
Z Manual Pulser Move: Manual Pulse motion. Clicking
this button invokes the manual pulse configuration win-
dow.
Z Home Mode: Home return motion. Clicking this button
invokes the home move configuration window. The
related function is _8164_set_home_config(). If the
ATU check box is checked, it will execute auto homing
when motion starts.
Z ERC Output: Select to send the ERC signal when home
move is completed.
Z EZ Count: Sets the EZ count number, which is effective
on certain home return modes.
Z Mode: Select from 13 home return modes.
Z Home Mode figure: The figure below explains the
actions of the individual home modes.
Z Close: Click this button to close the window.
Vista de pagina 169
1 2 ... 165 166 167 168 169 170 171 172 173 174 175 ... 309 310

Comentarios a estos manuales

Sin comentarios