Advance Technologies; Automate the World.
Manual Rev.: 3.10
Revision Date: Jan. 3, 2013
Part No: 50-1Z083-1010
MXC-6000
Fanless, Expandable Intel
®
Core™ i7-620LE
Processor 2.0 GHz Embedded Computer
User’s Manual
Vista de pagina 0
1 2 3 4 5 6 ... 99 100

Indice de contenidos

Pagina 1 - MXC-6000

Advance Technologies; Automate the World.Manual Rev.: 3.10Revision Date: Jan. 3, 2013Part No: 50-1Z083-1010MXC-6000Fanless, Expandable Intel® Core™

Pagina 2 - Revision History

xList of FiguresThis page intentionally left blank.

Pagina 3 - Table of Contents

88 Getting ServiceADLINK Technology, Inc. (French Liaison Office) Address: 15 rue Emile Baudot, 91300 Massy CEDEX, France Tel: +33 (0) 1 60 12 3

Pagina 4

xiMXC-6000PrefaceCopyright 2013 ADLINK Technology, Inc.This document contains proprietary information protected by copy-right. All rights are reserve

Pagina 5 - Table of Contents v

xiiConventionsTake note of the following conventions used throughout thismanual to make sure that users perform certain tasks andinstructions properly

Pagina 6

Introduction 1MXC-60001 Introduction1.1 OverviewThe Matrix MXC-6000 series provides powerful, fanless, expand-able embedded computing using the new I

Pagina 7 - List of Tables

2Introduction1.2 FeaturesX Intel® Core i7-620LE 2.0 GHz processor + Intel® QM57 chipsetX Expandable PCI and PCIe x4 slotsX Rugged, -10°C to 60°C fanle

Pagina 8

Introduction 3MXC-60001.3 SpecificationsMXC-6101D MXC-6201DSystem CoreProcessor Intel® Core i7-620LE 2.0 GHz CPUChipset Intel® QM57VideoOne DVI conne

Pagina 9 - List of Figures

4IntroductionAC Input Optional 100 W external AC-DC adapter for AC inputStorageSATA HDD 2 x Onboard SATA port for 2.5" HDD/SSD installationCF1x e

Pagina 10

Introduction 5MXC-6000Figure 1-1: MXC-6000 Functional Block DiagramSystem Full Load 78.72 WUnder Windows XP with 100% CPU utilization and simultaneou

Pagina 11

6Introduction1.4 Mechanical DrawingsThis section describes the appearance and connectors of theMXC-6000 controllers, including chassis dimensions, fro

Pagina 12 - Conventions

Introduction 7MXC-6000Figure 1-4: MXC-6000 Top ViewFigure 1-5: MXC-6000 Front View130.1182.8

Pagina 13 - 1 Introduction

iiRevision HistoryRevision Release Date Description of Change(s)3.00 Oct 5, 2012 Revised Specification3.10 Jan. 3, 2013 Paging Anomalies Rectified

Pagina 14 - 1.2 Features

8IntroductionFigure 1-6: MXC-6000 Rear ViewFigure 1-7: MXC-6000 Underside View4.011.091.016.515.9189.160.0

Pagina 15 - 1.3 Specifications

Introduction 9MXC-60001.5 Front Panel I/O Connectors.Figure 1-8: Front Panel I/O ConnectorA Power button I DVI-IB LED indicators J MIC & SpeakerC

Pagina 16

10 IntroductionTable 1-1: Front Panel I/O Connector Legend1.5.1 Power ButtonThe power button is a non-latched push button with a blue LEDindicator. S

Pagina 17 - Riser Card

Introduction 11MXC-6000nect) connector on the front panel. The onboard digital I/O cardsupports the following features:16-CH Isolated DIX Logic high:

Pagina 18 - 1.4 Mechanical Drawings

12 IntroductionTable 1-3: Digital I/O Connector Pin SignalsPINSignal NamePINSignal NamePINSignal Name1 VDD 24 IDI_1L 47 EOGND2 EOGND 25 IDI_0H 48 IDO

Pagina 19 - Figure 1-4: MXC-6000 Top View

Introduction 13MXC-6000Table 1-4: Digital I/O Connector Pin Legend1.6.1 Isolated Digital Input CircuitsInput accepts voltages up to 24V, with input

Pagina 20 - 8Introduction

14 IntroductionFigure 1-10: Isolated Digital Input Differential Input CircuitDIGNDPhotocoupler2.4KIDI_nHIDI_nL

Pagina 21

Introduction 15MXC-6000Figure 1-11: Isolated Digital Input Sample Application Circuit1.6.2 Isolated Digital Output CircuitsEach isolation digital out

Pagina 22 - 1.6 Digital I/O Connector

16 IntroductionThe VDD pin is connected in serial with a flywheel diode protectingthe driver during inductance loading, such as relay, motor, or sole-

Pagina 23 - Introduction 11

Introduction 17MXC-6000port page (driver for MXC-6000 DIO). PCIS-DASK containsWindows drivers, the API library, demo programs, and manuals. 1.6.4 Dig

Pagina 24

Table of Contents iiiMXC-6000Table of ContentsRevision History... iiList of Table

Pagina 25

18 IntroductionAddress: BASE + 0 to BASE + 1Attribute: read onlyData Format is as follows, wherein IDI_n is Isolated DigitalInput CH n.Digital Output

Pagina 26 - 14 Introduction

Introduction 19MXC-60001.6.5 USB 2.0 PortsThe MXC-6000 series controller provides four USB 2.0 ports sup-porting Type A USB connection on the front p

Pagina 27 - Introduction 15

20 IntroductionX Fully integrated ASF 2.0 functionality with on-chip µc X SMBus 2.0 master interface for ASF functionality X Preboot eXecution Environ

Pagina 28 - 16 Introduction

Introduction 21MXC-6000device for operating system files. Installation of a CF card isdescribed in Section 2.4: Installing CF Cards on page 40.1.6.8

Pagina 29 - CAUTION:

22 IntroductionTable 1-9: DVI-I Connector SignalsCAUTION:Since VGA signals are analog based, VGA display quality is greatly affected by quality and l

Pagina 30

Introduction 23MXC-60001.6.10 Audio JacksThe MXC-6000 series controller implements Intel High Definitionaudio on a Realtek ALC262 chip. The HD audio

Pagina 31 - 1.6.5 USB 2.0 Ports

24 Introduction1.6.12 eSATA connectorThe MXC-6000 controller provides one eSATA port connector onthe front panel. The MXC-6000 series supports externa

Pagina 32 - 1.6.7 CompactFlash Socket

Introduction 25MXC-6000Table 1-12: DC Power Supply Connector Signals1.6.14 PCI slotThe MXC-6201 provides one PCI slot, and the MXC-6101 pro-vides tw

Pagina 33 - 1.6.9 DVI-I connector

26 Introduction1.7 Internal I/O connectorsThis section describes the internal I/O connectors of theMXC-6000 series controller, as shownFigure 1-14: Ma

Pagina 34

Introduction 27MXC-6000Figure 1-15: Backplane Board PCBTable 1-14: Backplane Board Connector LegendA PCI express x4 slotBPCI slotC Internal USB conn

Pagina 35 - 1.6.10 Audio Jacks

iv Table of Contents1.6.14 PCI slot ... 251.6.15 PCI express x4 slot...

Pagina 36 - 1.6.13 DC Power connector

28 Introduction1.7.1 Clear CMOS JumperUpon encountering an abnormal condition preventing theMXC-6000 series from booting, the jumper can clear the BIO

Pagina 37 - 1.6.15 PCI express x4 slot

Introduction 29MXC-60001.7.3 Internal CF Card ConnectorThe Matrix MXC-6000 series is equipped with an internal Com-pactFlash socket, converted from S

Pagina 38 - 1.7 Internal I/O connectors

30 Introduction1.7.4 LVDS Interface ConnectorThe MXC-6000 series controller provides an internal LVDS inter-face connector. The LVDS interface can sup

Pagina 39

Introduction 31MXC-60001.7.5 12V DC Fan ConnectorThe MXC-6000 series controller provides a DC 12V to USB con-nector for fan module power. The optiona

Pagina 40 - 1.7.1 Clear CMOS Jumper

32 Introduction1.7.7 Internal USB ConnectorThe MXC-6000 series controller provides an internal USB connec-tor on the back board PCB.1.7.8 SATA Connect

Pagina 41 - Introduction 29

Getting Started 33MXC-60002 Getting StartedThis chapter discusses installation of a hard disk drive, a PCI/PCIecard, and two CompactFlash cards in th

Pagina 42 - LVDS signals

34 Getting Started2.2 Installing Hard Disk DrivesBefore installing hard disk drives, remove the top cover of the chas-sis first as follows.1. Remove t

Pagina 43 - 1.7.5 12V DC Fan Connector

Getting Started 35MXC-60002. Withdraw the thumbscrew and remove the top cover bylifting.3. Remove 2 screws from the top of the HDD bracket.

Pagina 44 - 1.7.8 SATA Connectors

36 Getting Started4. Place the chassis upside down and remove the other 2screws from the bottom of the HDD bracket..5. Lift the HDD bracket..6. Use th

Pagina 45 - 2 Getting Started

Getting Started 37MXC-60002.5’’ HDD or SSD is SATA Revision 1, and the lowerSATA Revision 2.7. Gently push the HDD/SSD bracket down to the SATA con-n

Pagina 46 - 34 Getting Started

Table of Contents vMXC-6000A.1 Power Consumption Reference... 55A.2 Power Supply Reference ...

Pagina 47 - Getting Started 35

38 Getting Started2.3 Installing a PCI/PCIe CardFollow steps 1-2 in Section 2.2:Installing Hard Disk Drives toremove the top cover before installing a

Pagina 48 - 5. Lift the HDD bracket

Getting Started 39MXC-6000Tighten the screw to fix the brace.3. Replace the top cover and fasten the thumbscrew.

Pagina 49 - Getting Started 37

40 Getting Started2.4 Installing CF CardsThe MXC-6000 series controller provides internal and externalCompactFlash sockets to accommodate a total of t

Pagina 50 - 38 Getting Started

Getting Started 41MXC-60003. Place the two spacer supports, included as accessories,to prevent the CF card from dislodging.4. Replace the top cover a

Pagina 51 - Getting Started 39

42 Getting Started5. Remove the external CF socket cover.6. Align the externally mounted CF card with the guide ofthe external CF socket.7. Gently ins

Pagina 52 - 2.4 Installing CF Cards

Getting Started 43MXC-6000external CF socket, as indicated by the extension of theeject button below the card slot, as shown.

Pagina 53 - Getting Started 41

44 Getting Started2.5 Connecting and Using eSATA Storage Device1. Plug an eSATA cable into the eSATA connector.2. Connect the eSATA cable and a DC pow

Pagina 54 - 42 Getting Started

Getting Started 45MXC-6000external storage device.2.6 Connecting DC PowerThe DC power input connector of the MXC-6000 series controllerhas V+, V- , a

Pagina 55 - Getting Started 43

46 Getting Started2.7 Wall-mounting the MXC-6000The MXC-6000 series controller is shipped with wall-mount brack-ets and accessory screws.Wall–mounting

Pagina 56 - 44 Getting Started

Getting Started 47MXC-60002. Use the 4 M4 screws shipped with the controller to fixthe 2 wall-mount brackets, also included, to the chassis,according

Pagina 57 - 2.6 Connecting DC Power

vi Table of ContentsC Appendix: Activating RAID Function...65C.1 RAID Activation in System Manangement...

Pagina 58 - 46 Getting Started

48 Getting Started3. Once final assembly as shown is complete, mount theMXC-6000 series controller on the wall via screw holes.5.27.210.05.225.2

Pagina 59 - Getting Started 47

Getting Started 49MXC-60002.8 Optional Fan ModuleThe MXC-6000 can be optionally equipped with an easily installedfan module providing heat dissipatio

Pagina 60 - 48 Getting Started

50 Getting Started2. Slide the fan module back until USB connection issecured, as shown.3. Replace the thumbscrew.2.9 Cooling ConfigurationHeat-genera

Pagina 61 - 2.8 Optional Fan Module

Driver Installation 51MXC-60003 Driver InstallationAfter installing the operating system, all related drivers must beinstalled for the system to func

Pagina 62 - 2.9 Cooling Configuration

52 Driver InstallationThe following steps install the chipset driver for the MXC-6000series controller1. Close any running applications. 2. Insert the

Pagina 63 - 3 Driver Installation

Driver Installation 53MXC-6000For Microsoft Windows 7and XP users:1. Close any running applications.2. Insert the ADLINK All-in-One DVD. The Ethernet

Pagina 64 - 52 Driver Installation

54 Driver InstallationTo install the WDT driver for the MXC-6000 series controller:1. Close any running applications.2. Insert the ADLINK All-in-One D

Pagina 65 - 3.5 Installing the WDT driver

Power Consumption 55MXC-6000Appendix A: Power ConsumptionA.1 Power Consumption ReferencePower consumption as follows is based on lab data in which 24

Pagina 66 - 3.6 Installing the DIO Driver

56 Power ConsumptionA.2 Power Supply ReferenceTable A-2: Power SupplySufficient power supply for the entire system is required to meetthese specifica

Pagina 67 - Appendix A: Power Consumption

BIOS Setup 57MXC-6000Appendix B: BIOS SetupThe Basic Input/Output System (BIOS) is a program that providesa basic level of communication between the

Pagina 68 - A.3 Accessory Cabling

List of Tables viiMXC-6000List of TablesTable 1-1: Front Panel I/O Connector Legend... 10Table 1-2: LED Indicators ...

Pagina 69 - Appendix B: BIOS Setup

58 BIOS SetupSystem DateShows the current date based on the system’s Real TimeClock, and can be adjusted if RTC is not synched to the currentdate.Syst

Pagina 70 - B.2 Advanced

BIOS Setup 59MXC-6000DVMT/FIXED MemorySets the amount of memory allocated to IGD, with availableoptions of 128 or 256MB, or Maximum.IGD – Boot TypeSe

Pagina 71 - B.2.1 ACPI Settings

60 BIOS SetupActive LFPEnables or disables Internal LVDs.LCD Panel TypeSelect the LCD panel used by LVDs by the appropriate setup item.Options include

Pagina 72 - B.2.3 CPU Configuration

BIOS Setup 61MXC-6000B.2.4 SATA ConfigurationSATA ModeThis option selects the SATA channel configuration from (1) IDEMode (2) AHCI Mode or (3) RAID M

Pagina 73 - B.2.7 Watchdog Timer

62 BIOS SetupEnables/ disables the watchdog timerB.2.8 H/W MonitorPC Health StatusThe hardware health on SuperIO supports System Temperature,CPU Tempe

Pagina 74 - B.3 Chipset

BIOS Setup 63MXC-6000Table B-1: Restore On Power LossB.4 SecurityIf only the Administrator’s password is set, then only access toSetup is limited an

Pagina 75 - B.5 Boot

64 BIOS SetupQuiet BootBootup Num-Lock StateSet this value to allow the Number Lock setting to be modified dur-ing boot.B.5.2 Boot Option PrioritiesSp

Pagina 76 - B.6 Exit

Activating RAID Function 65MXC-6000Appendix C: Activating RAID FunctionThe Matrix MXC-6000 utilizes Intel® Rapid Storage Technologyprovided by the In

Pagina 77

66 Activating RAID FunctionEnsure all data on the disks to be used in the RAID array is fullybacked up.Refer to Section 2.2 to install the two hard di

Pagina 78 - “Advanced” tab

Activating RAID Function 67MXC-60002. Set SATA Mode to “RAID Mode”, and save and exitBIOS.

Pagina 79 - Activating RAID Function 67

viii List of TablesThis page intentionally left blank.

Pagina 80 - Manager appears in POST

68 Activating RAID FunctionC.1.1 Intel Matrix Storage ManagerAfter the SATA is set to RAID mode, the Intel Matrix StorageManager appears in POST. 1. S

Pagina 81 - Activating RAID Function 69

Activating RAID Function 69MXC-6000The menu lists the 2 installed HDDs as “Non-RAID Disk” since theRAID volume has not yet been created.2. Select “Cr

Pagina 82 - RAID volume list

70 Activating RAID Functionfigure other parameters. Select “Create Volume”. Alldata will be erased from the HDD.4. After the RAID Volume is created, i

Pagina 83 - C.2 OS Activation

Activating RAID Function 71MXC-6000C.2 OS ActivationC.2.1 Windows XPDownload the MXC-6000 RAID drivers from the ADLINK website,unzip, and copy the fi

Pagina 84 - 72 Activating RAID Function

72 Activating RAID Function2. When an additional device driver is requested, press S.An Intel controller list is displayed.

Pagina 85 - Mobile Express Chipset

Activating RAID Function 73MXC-60003. From the list, select “Intel® Mobile Express ChipsetSATA RAID Controller”. Required drivers are copiedfrom the

Pagina 86 - C.2.2 Windows 7

74 Activating RAID Function4. The Intel® Mobile Express Chipset SATA RAID Control-ler is displayed in the mass storage device list. OSInstallation can

Pagina 87 - Activating RAID Function 75

Activating RAID Function 75MXC-6000Navigate to the driver files and select OK to load.

Pagina 88 - 76 Activating RAID Function

76 Activating RAID FunctionSelect Intel Mobile Express Chipset SATA RAID Controller. Therequired drivers are then copied. After the drivers are loaded

Pagina 89 - Function Library

Watchdog Timer (WDT) Function Library 77MXC-6000Appendix D: Watchdog Timer (WDT)Function LibraryThis appendix describes use of the watchdog timer (WD

Pagina 90

List of Figures ixMXC-6000List of FiguresFigure 1-1: MXC-6000 Functional Block Diagram ... 5Figure 1-2: MXC-6000 Left Side View

Pagina 91 - ResetWDT

78 Watchdog Timer (WDT) Function LibrarySetWDT@ DescriptionSet the timeout value of the watchdog timer. There are twoparameters for this function to i

Pagina 92 - D.2 WDT with DOS/Linux

Watchdog Timer (WDT) Function Library 79MXC-6000StartWDT @ DescriptionStart the watchdog timer function. Once the StartWDT isinvoked, the watchdog ti

Pagina 93

80 Watchdog Timer (WDT) Function Library@ ParametersNone@ Return codesTRUE if watchdog timer is successfully reset.FALSE if watchdog timer fails to re

Pagina 94

Watchdog Timer (WDT) Function Library 81MXC-6000outp(0x2E, 0x87);outp(0x2E, 0x87);}/* Config LPC IO to exit config mode */ExitConfig(void){outp(0x2E,

Pagina 95

82 Watchdog Timer (WDT) Function Libraryprintf("---------------------------------------------------\n");EnterConfig();/* config WDT register

Pagina 96

Watchdog Timer (WDT) Function Library 83MXC-6000{printf("Countdown %2d : 0xF6=%2x Press any key toinvoke keyboard interrupt.\n",count,r_reg

Pagina 97 - Important Safety Instructions

84 Watchdog Timer (WDT) Function LibraryThis page intentionally left blank.

Pagina 98 - WARNING:

Important Safety Instructions 85MXC-6000Important Safety InstructionsFor user safety, please read and follow all instructions,WARNINGS, CAUTIONS, an

Pagina 99 - Getting Service

86 Important Safety InstructionsX Never attempt to fix the equipment. Equipment should only be serviced by qualified personnel.A Lithium-type battery

Pagina 100 - 88 Getting Service

Getting Service 87MXC-6000Getting ServiceContact us should you require any service or assistance. ADLINK Technology, Inc. Address: 9F, No.166 Jian