Page 18 Express-CVC
3.3.3. LVDS
Signal Pin Description I/O PU/PD Comment
LVDS_A0+
LVDS_A0-
LVDS_A1+
LVDS_A1-
LVDS_A2+
LVDS_A2-
LVDS_A3+
LVDS_A3-
A71
A72
A73
A74
A75
A76
A78
A79
LVDS Channel A differential pairs O LVDS
LVDS_A_CK+
LVDS_A_CK-
A81
A82
LVDS Channel A differential clock O LVDS
LVDS_B0+
LVDS_B0-
LVDS_B1+
LVDS_B1-
LVDS_B2+
LVDS_B2-
LVDS_B3+
LVDS_B3-
B71
B72
B73
B74
B75
B76
B77
B78
LVDS Channel B differential pairs O LVDS
LVDS_B_CK+
LVDS_B_CK-
B81
B82
LVDS Channel B differential clock O LVDS
LVDS_VDD_EN A77 LVDS panel power enable O 3.3V
LVDS_BKLT_EN B79 LVDS panel backlight enable O 3.3V
LVDS_BKLT_CTRL B83 LVDS panel backlight brightness control O 3.3V
LVDS_I2C_CK A83 DDC lines used for flat panel detection and control. O 3.3V PU 2k2 3.3V
LVDS_I2C_DAT A84 DDC lines used for flat panel detection and control. I/O 3.3V
PU 2k2 3.3V
3.3.4. Gigabit Ethernet
Gigabit Ethernet Pin Description I/O PU/PD Comment
GBE0_MDI0+
GBE0_MDI0-
GBE0_MDI1+
GBE0_MDI1-
GBE0_MDI2+
GBE0_MDI2-
GBE0_MDI3+
GBE0_MDI3-
A13
A11
A10
A9
A7
A6
A3
A2
Gigabit Ethernet Controller 0: Media Dependent Interface Differential
Pairs 0, 1, 2, 3. The MDI can operate in 1000, 100, and 10Mbit/sec
modes. Some pairs are unused in some modes according to the
following:
1000BASE-T 100BASE-TX 10BASE-T
MDI[0]+/- B1_DA+/- TX+/- TX+/-
MDI[1]+/- B1_DB+/- RX+/- RX+/-
MDI[2]+/- B1_DC+/-
MDI[3]+/- B1_DD+/-
I/O Analog Twisted
pair signals
for external
transformer
.
GBE0_ACT# B2 Gigabit Ethernet Controller 0 activity indicator, active low.
OD 3.3VSB PU 1k 3.3V
GBE0_LINK# A8 Gigabit Ethernet Controller 0 link indicator, active low.
OD 3.3VSB
GBE0_LINK100# A4 Gigabit Ethernet Controller 0 100Mbit/sec link indicator, active low.
OD 3.3VSB
GBE0_LINK1000# A5 Gigabit Ethernet Controller 0 1000Mbit/sec link indicator, active low.
OD 3.3VSB
GBE0_CTREF A14 Reference voltage for Carrier Board Ethernet channel 1 and 2
magnetics center tap. The reference voltage is determined by the
requirements of the Module PHY and may be as low as 0V and as high
as 3.3V. The reference voltage output shall be current limited on the
Module. In the case in which the reference is shorted to ground, the
current shall be 250 mA or less.
GND min
3.3V max