20
Registers Format
3.3 A/D Channel Multiplexer Register
This register is used to control the A/D channels number to convert. It's a
write only register. When the channel number is written to the register, the
multiplexer switches to the new channel and waits for conversion.
Address: BASE + 10
Attribute:
write only
Data Format:
Bit 7 6 5 4 3 2 1 0
BASE+10 X X X X X CL2 CL1 CL0
CLn: multiplexer channel number.
CL2 is MSB, and CL0 is LSB.
Where CL2, CL1, and CL0 are multiplexer channel selection:
Channel NO. CL2 CL1 CL0
0 0 0 0 Power Up Setting
1 0 0 1
2 0 1 0
3 0 1 1
4 1 0 0
5 1 0 1
6 1 1 0
7 1 1 1